Leaking waste pipe joint found in the ceiling void

Reported problem

Dripping from the bathroom ceiling below whenever the bathroom above was used.

Inspection findings

Two failed joints on the waste pipe run inside the ceiling void: the floor trap outlet and an elbow further along.

Testing conducted

Ceiling panel opened, flow test run through the shower and floor trap above, leak points marked as the water appeared.

Repair scope

Old fittings cut out, waste pipe run replaced with new pipework and solvent-welded joints, flow test repeated dry.

Outcome

No further dripping. Ceiling panel reinstated after the monitoring period.